Home » Products » CHL

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

CHL

Availability:
Materias

Materials Provided

Test tubes

Sterile polyester tipped  applicator (Sterile

female cervical swabs)

Reagent B

Package insert

Sterile male cervical swabs

Negative control

Centrifuge tube (for male urine specimens only)


Directions For Use

Allow the test device, specimen, reagents, and/or controls to reach room temperature (15‐ 30 C) prior to testing.

1. Remove the test device from the sealed foil pouch and use it as soon as possible. Best results will be obtained if the test is performed immediately after opening the foil pouch.

2. Extract the Chlamydia antigen:

For Female Cervical or Male Urethral Swab Specimens:

  Hold the Reagent A bottle vertically and add 4 full drops of Reagent A (approximately 280 µL) to the extraction tube(See illustration ①). Reagent A is colorless. Immediately insert the swab, compress the bottom of the tube and rotate the swab 15 times. Let stand for 2 minutes. (See illustration ②)

Hold the Reagent B bottle vertically and add 4 full drops Reagent B (approximately 240ul) to the extraction tube. (See illustration ③) Reagent B is pale yellow. The solution will turn cloudy. Compress the bottom of tube and rotate the swab 15 times until the solution turns to a clear color with a slight green or blue tint. If the swab is bloody, the color will turn yellow or brown. Let stand for 1 minute. (See illustration ④)

  Press the swab against the side of the tube and withdraw the swab while squeezing the tube. (See illustration ⑤).Keep as much liquid in the tube as possible. Fit the dropper tip on top of the extraction tube. (See illustration ⑥)



For Male Urine Specimens:

 Hold the Reagent B bottle vertically and add 4 full drops Reagent B (approximately 240ul) to the urine pellet in the centrifuge tube, then shake the tube vigorously mix until the suspension is homogeneous.

 Transfer all the solution in the centrifuge tube to an extraction tube. Let stand for 1 minute. Hold the Reagent A bottle upright and add 4 full drops of Reagent A (approximately 280 µL) then add to the extraction tube. Vortex or tap the bottom of the tube to mix the solution. Let stand for 2 minutes.

 Fit the dropper tip on top of the extraction tube.

3. Place the test device on a clean and level surface. Add 3 full drops of extracted solution (approximately 100 µL) to the specimen well (S) of the test device, then start the timer. Avoid trapping air bubbles in the specimen well (S).

4. Wait for the red line(s) to appear. Read the result at 10 minutes. Do not read the result after

20 minutes.


Interpretation Of Results

POSITIVE RESULT:


C

T

NEGATIVE RESULT: C

T

INVALID RESULT: C

T

* A colored band  appears in the control band region (C) and another colored band appears in the T band region.


One colored band appears in the control band region (C). No band appears in the test band region (T).

Control band fails to appear. Results from any test which has not produced  a control band at the specified reading time must be discarded. Please review the procedure and repeat with a  new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.

*NOTE: The intensity of the red color in the test line region (T) may vary depending on the concentration of Chlamydia antigen presents in the specimen. Therefore, any shade of red in the test region (T) should be considered positive.

通用-1通用-2通用


Previous: 
Next: 
CHL
KeyGEN BioTECH is committed to providing trustworthy instruments and services for the explorers in life science...

QUICK LINKS

CONTACT US

  +86-15806185350
  daynakeygen@163.com
  +86-25-84985136
  Building 6, No.18, Zhilan Road, Jiangning Science Park, Jiangning District,Nanjing City, Jiangsu Province, China
Copyright © 2022 Jiangsu KeyGEN BioTECH CO.,Ltd. Technology by Leadong. Sitemap.

SUBSCRIBE